Uncategorized

I like to contact the following department:

[checkbox* contact_department exclusive “ACCOUNTING” “SALES” “RMA” “RFQ” “TECH-SUPPORT” “OTHERS”]

Regarding the following Product Line

[checkbox* product_line “Assemblies” “Current Sensors” “Coils & Spuls ” “Embedded Systems” “Inductors” “Laboratory Instruments/Oscilloscopes” “Panel Instrumentation” “PCB Boards” “Power Supplies” “Relays”
“Transformers” “Others” ]

[date* message_date]

My Credentials and Contact Information

Pronouns* [radio gender_pronouns default:1 “Mrs.” “Miss” “Mr.” ]
First Name* [text* first_name maxlength:40 autocomplete:given-name placeholder “My First Name”]
Last Name* [text* last_name maxlength:40 autocomplete:family-name placeholder “My Last Name”]
email* [email* sender_email maxlength:60 autocomplete:email placeholder “MyEmail@mydomain.com”]
Web Page URL* [url* sender_web_url maxlength:60 autocomplete:email placeholder “https://mydomain.com”]
Telephone Number: Country Code – Area Code – Number and extension

Company Name* [text* sender_Company placeholder “My Company Name”]
Country* [text* sender_Country “USA”]
[text* sender_subject placeholder “My Subject”]
[textarea sender_message x6 placeholder “My Message”]

You can attach Text or PDF files up to 2MB

[file sender_file filetypes:pdf|txt limit:2mb]


How did you hear from us?*[select* HowDoYouKnowUs include_blank “I’m an Existing Customer” “Received Ascend Electronics email” “From Google/Web Search” “From a Referral” “From Thomas Net” “From Trade Show” “Others”]
[submit “SEND MESSAGE”]

1
INQUIRY FROM AEI WEBPAGE :[first_name] [last_name]
([first_name] [last_name]) AEI WEB
info@ascendelec.com





AEI LOGO

AEI AUTOMATED MESSAGE

THIS IS AN AUTOMATED MESSAGE SEND OUT BY AEI TECHWEB TO NOTIFY THAT
AN CUSTOMER MADE A SALES OR INFORMATION REQUEST.

ONLINE INQUIRY HASE BEEN MADE.

__________________________________________________________________________

An ONLINE INQUIRY requested is made from the Ascend Electronics Contact Us Form Page

From: [first_name] [last_name] <[sender_email]>
Subject: [sender_subject]
Date: [message_date]

__________________________________________________________________________

MESSAGE

Gender: [gender_pronouns]
First Name: [first_name]
Last Name: [last_name]
==> [gender_pronouns] [first_name] [last_name]
email address: [sender_email]
Phone Number: [sender_phone_areacode]-[sender_phone_number] ext [sender_phone_extension]
Company: [sender_Company]
URL [sender_web_url]
Company: [sender_Company]
Country: [sender_Country]
Does Know us from [HowDoYouKnowUs]
For Department: [contact_department]
Product Lines: [product_line]
Message Body: [sender_message]

This e-mail was sent from a contact form the Contact Us – Main Web Site on Ascend Electronics (https://ascendeleccom.wordpress.arltis.net/contact-us/)

_____________________________________________________________________________________

END OF EMAIL

_____________________________________________________________________________________




Reply-To: [sender_email]
Cc:
[sender_file]
1
1
1
RE: [sender_subject]
ASCEND ELECTRONICS
[sender_email]





AEI LOGO

ASCEND ELECTRONICS® AUTOMATED MESSAGE

THIS IS AN AUTOMATED MESSAGE SENT OUT BY ASCEND ELECTRONICS®
TO NOTIFY YOU THAT WE RECEIVED YOUR INQUIRY.

_________________________________________________________________________________

Dear [gender_pronouns] [first_name] [last_name],

Thank you for contacting Ascend Electronics®.
We received the following message from you:

Date: [message_date]
Subject: [sender_subject]
For Department: [contact_department]
Product Lines: [product_line]
Your Message: [sender_message]

Thank you very much,
Ascend Electronics®



1
1
Your message was sent successfully. Thanks.
Failed to send your message. Please try later or contact the administrator by another method.
Validation errors occurred. Please confirm the fields and submit it again.
Failed to send your message. Please try later or contact the administrator by another method.
Please accept the terms to proceed.
Please fill in the required field.
This input is too long.
This input is too short.
Failed to upload file.
This file type is not allowed.
This file is too large.
Failed to upload file. Error occurred.
Date format seems invalid.
This date is too early.
This date is too late.
Number format seems invalid.
This number is too small.
This number is too large.
Your answer is not correct.
Email address seems invalid.
URL seems invalid.
Telephone number seems invalid.

There are no posts on the list.
✕

AUTO TRANSFORMERS

Autotransformer

An autotransformer has a single winding with two end terminals and one or more terminals at intermediate tap points. It is a transformer in which the primary and secondary coils have part of their turns in common. The portion of the winding shared by both the primary and secondary is the common section. Autotransformers have no galvanic isolation!

✕
✕

Isolation Transformer

Isolation Transformer

An isolation transformer is a transformer used to transfer electrical power from a source of alternating current (AC) power to some equipment or device while isolating the powered device from the power source, usually for safety reasons (or to reduce transients and harmonics). Isolation transformers provide galvanic isolation. Therefore no conductive path is present between the source and the load.

✕

Toroidal Transformer

Toroidal Transformer

A toroidal transformer is an electrical transformer constructed with a torus or donut-shaped core. Its primary and secondary windings are wound across the entire surface of the torus core, separated by an insulating material. This configuration minimizes the magnetic flux leakage. All Ascend Electronics toroidal transformers are constructed as isolation transformers.

 
✕

Air-Core Transformers

Air-Core Transformers

Air-core transformers are designed to transfer energy or radio-frequency currents (currents used for radio transmission). Air-core transformers consist of two or more coils wound around a solid insulating substance or on an insulating coil form and have no magnetic core. Therefore, air-core transformers have a weak energy transmission ratio.


✕
✕

Transformer Efficiency

Transformer Efficiency


The ratio of a transformer's output power to its input power is known as transformer efficiency. The effect of transformer losses is measured by transformer efficiency, typically expressed as a percentage.

✕

Voltage Regulation

Transformer Voltage Regulation


Transformer voltage regulation is the ratio or percentage value by which a transformer's output terminal voltage varies either up or down from its no-load value due to variations in the connected load current.

✕

Ambient Operating Temperature

Ambient Operating Temperature

The ambient temperature is the temperature at a location not affected by the heat generated by the transformer itself.

✕

Transformer Temperature Rise

Transformer Temperature Rise

Transformer temperature rise is defined as the average temperature rise of the windings above the ambient (surrounding) temperature when the transformer is loaded at its nameplate rating.

✕

High Voltage Isolation Class

High Voltage Isolation Class

The high-voltage isolation class is used during the transformers' high-pot tests. High-pot (High Potential) tests, also known as dielectric withstand tests, are used to apply high voltage to assets to determine the adequacy of the electrical insulation to withstand voltage transients and ensure the insulation is not marginal. In addition, the voltage class is used to define high-voltage potential differential operation between primary and secondary.

✕

Input Waveforms

Input Waveforms


The transformer induces power or signal voltage waveforms for each secondary output. The resulting output waveform will be the same shape and frequency as its input waveform. Note that all transformers have bandpass characteristics, meaning they have a low-end and high-end frequency roll-off. Therefore for transformers outside the standard AC power line (50Hz to 400Hz), such as audio (20Hz-20kHz) and switching (1kHz to 10MHz), the minimum and maximum frequency of the bandwidth must be specified, in addition to the input waveform, such as pulse (square) or sinus.

✕

UNDER CONSTRUCTION

The page is temporary not available. Will be up soon